Search results for "RING-DOWN SPECTROSCOPY"
showing 5 items of 5 documents
A comparison of HONO budgets for two measurement heights at a field station within the boreal forest in Finland
2015
Atmospheric concentrations of nitrous acid (HONO), one of the major precursors of the hydroxyl radical (OH) in the troposphere, significantly exceed the values predicted by the assumption of a photostationary state (PSS) during daytime. Therefore, additional sources of HONO were intensively investigated in the last decades. This study presents budget calculations of HONO based on simultaneous measurements of all relevant species, including HONO and OH at two different measurement heights, i.e. 1 m above the ground and about 2 to 3 m above the canopy (24 m above the ground), conducted in a boreal forest environment. We observed mean HONO concentrations of about 6.5 × 108 molecules cm−3 (26 p…
Whispering gallery mode resonator sensors referenced to saturated absorption lines in rubidium atoms and a fs frequency comb
2019
Optical Whispering Gallery Mode Resonators (WGMR) can be produced by many methods, for example, by flame melting of silica fibers [1], by polishing of crystals [2], by optical lithography, by solidifying transparent materials, or using commercially available microspheres. They confine light by the total internal reflection and do not need mirror coatings. A part of radiation is traveling outside the WGMR as an evanescent wave and it is used for sensing applications. WGMRs are becoming increasingly popular as biosensors [3] when their surface is covered with antibodies to provide selectivity. Advantage is that light circulates in the resonator and interacts many times with a few molecules at…
First results of cavity ring down signals from exhaled air
2017
In this paper we report first results from the developed cavity ring-down spectrometer for application in human breath analysis for the diagnostics of diabetes and later for early detection of lung cancer. Our cavity ring-down spectrometer works in UV region with pulsed Nd:YAG laser at 266 nm wavelength. First experiments allow us to determine acetone and benzene at the level bellow ppm. In our experiment, first results from breath samples from volunteers after doing different activities were collected and examined. Influence of the smoking on the breath signals also was examined.
Cavity Ring-Down Spectroscopy measurements of Acetone concentration
2017
This research has been partly supported by the National Research Programme "The next generation of information and communication technologies" (NexIT).
Methane line parameters in the HITRAN2012 database
2013
International audience; The compilation of methane molecular line parameters was updated to include new global analyses and measurements for 12CH4, 13CH4 and 12CH3D. Over 70% of the methane parameters in HITRAN2008 were replaced; existing parameters retained were the microwave lines and the Dyad of 13CH4 near 7 μm and ν6 of 13CH3D near 8.7 μm, 12CH3D (7-4076 cm-1), hot bands of 12CH4 (1887-3370 cm-1) and normal sample CH4 (4800-5550 cm-1 and 8000-9200 cm-1). With a minimum intensity at 296 K in units of cm-1/(molecule cm-2) set to 10-37 for the far-IR and 10-29 for the mid- and near-IR, the methane database increased from 290,091 lines in HITRAN2008 to 468,013 lines, and three-fourths of th…