Search results for "RING-DOWN SPECTROSCOPY"

showing 5 items of 5 documents

A comparison of HONO budgets for two measurement heights at a field station within the boreal forest in Finland

2015

Atmospheric concentrations of nitrous acid (HONO), one of the major precursors of the hydroxyl radical (OH) in the troposphere, significantly exceed the values predicted by the assumption of a photostationary state (PSS) during daytime. Therefore, additional sources of HONO were intensively investigated in the last decades. This study presents budget calculations of HONO based on simultaneous measurements of all relevant species, including HONO and OH at two different measurement heights, i.e. 1 m above the ground and about 2 to 3 m above the canopy (24 m above the ground), conducted in a boreal forest environment. We observed mean HONO concentrations of about 6.5 × 108 molecules cm−3 (26 p…

Meteorologie en Luchtkwaliteit1171 Geosciences4112 ForestryPHOTOLYSIS FREQUENCYMeteorology and Air Qualityeducation116 Chemical sciencesBOUNDARY-LAYERSURFACE-ADSORBED HNO3HETEROGENEOUS HYDROLYSISGAS-PHASE114 Physical scienceslcsh:QC1-999lcsh:ChemistryRING-DOWN SPECTROSCOPYNITRIC-ACIDVERTICAL GRADIENTSlcsh:QD1-999ddc:550Life ScienceNITROUS-ACID HONOATMOSPHERIC CHEMISTRY1172 Environmental scienceslcsh:Physics
researchProduct

Whispering gallery mode resonator sensors referenced to saturated absorption lines in rubidium atoms and a fs frequency comb

2019

Optical Whispering Gallery Mode Resonators (WGMR) can be produced by many methods, for example, by flame melting of silica fibers [1], by polishing of crystals [2], by optical lithography, by solidifying transparent materials, or using commercially available microspheres. They confine light by the total internal reflection and do not need mirror coatings. A part of radiation is traveling outside the WGMR as an evanescent wave and it is used for sensing applications. WGMRs are becoming increasingly popular as biosensors [3] when their surface is covered with antibodies to provide selectivity. Advantage is that light circulates in the resonator and interacts many times with a few molecules at…

Total internal reflectionMaterials scienceAbsorption spectroscopybusiness.industryPolishing01 natural sciences010305 fluids & plasmasCavity ring-down spectroscopylaw.inventionFrequency combResonatorlaw0103 physical sciencesOptoelectronicsWhispering-gallery wavePhotolithography010306 general physicsbusiness
researchProduct

First results of cavity ring down signals from exhaled air

2017

In this paper we report first results from the developed cavity ring-down spectrometer for application in human breath analysis for the diagnostics of diabetes and later for early detection of lung cancer. Our cavity ring-down spectrometer works in UV region with pulsed Nd:YAG laser at 266 nm wavelength. First experiments allow us to determine acetone and benzene at the level bellow ppm. In our experiment, first results from breath samples from volunteers after doing different activities were collected and examined. Influence of the smoking on the breath signals also was examined.

Materials scienceSpectrometerAnalytical chemistryEarly detectionLaserExhaled airlaw.inventionCavity ring-down spectroscopychemistry.chemical_compoundBreath gas analysischemistrylawRing downBenzeneBiophotonics—Riga 2017
researchProduct

Cavity Ring-Down Spectroscopy measurements of Acetone concentration

2017

This research has been partly supported by the National Research Programme "The next generation of information and communication technologies" (NexIT).

History010308 nuclear & particles physicsHigh reflectivityAnalytical chemistryPulse duration01 natural sciencesSystem a3. Good healthComputer Science ApplicationsEducationCavity ring-down spectroscopychemistry.chemical_compoundchemistry0103 physical sciencesDiode-pumped solid-state laserAcetone:NATURAL SCIENCES:Physics [Research Subject Categories]010306 general physicsSpectroscopy
researchProduct

Methane line parameters in the HITRAN2012 database

2013

International audience; The compilation of methane molecular line parameters was updated to include new global analyses and measurements for 12CH4, 13CH4 and 12CH3D. Over 70% of the methane parameters in HITRAN2008 were replaced; existing parameters retained were the microwave lines and the Dyad of 13CH4 near 7 μm and ν6 of 13CH3D near 8.7 μm, 12CH3D (7-4076 cm-1), hot bands of 12CH4 (1887-3370 cm-1) and normal sample CH4 (4800-5550 cm-1 and 8000-9200 cm-1). With a minimum intensity at 296 K in units of cm-1/(molecule cm-2) set to 10-37 for the far-IR and 10-29 for the mid- and near-IR, the methane database increased from 290,091 lines in HITRAN2008 to 468,013 lines, and three-fourths of th…

Materials science010504 meteorology & atmospheric sciencesPlanetscomputer.software_genre01 natural sciencesSpectral lineMethaneCavity ring-down spectroscopy010309 opticschemistry.chemical_compoundLine parameters0103 physical sciencesIsotopologueSpectroscopy0105 earth and related environmental sciencesLine (formation)[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]RadiationDatabaseDifferential optical absorption spectroscopyExoplanetsRemote sensingAtomic and Molecular Physics and OpticschemistryHITRAN databaseAtomic physicsGround statecomputerMethaneMicrowaveJournal of Quantitative Spectroscopy and Radiative Transfer
researchProduct